PAT-Cell for in-situ gas analysis in a flow-through set-up

•PAT series test cell with gas inlet and outlet
•Lower plungers with perforated plate and with spiral-shaped flow field for optimized plug-flow available.
•Optional laser-welded pressure sensor, 0 to 3 bar abs.
分享:

PAT-Cell for in-situ gas analysis in a flow-through set-up

Our versatile test cell for in-situ gas analysis
The PAT-Cell-Gas is a test cell dedicated to the in-situ gas analysis of battery materials in a flow-through setup. It combines all capabilities of the ECC-Air, ECC-DEMS and PAT-Cell-Press test cells. For this purpose, the test cell features a gas inlet and outlet with self-locking couplings that are compatible with 1/16 in. Swagelok tube fittings. In addition, options that include a built-in pressure sensor or a valve port for gas sampling with a syringe are also available.

The cell stack is placed on top of a perforated or grooved current collector (flow field), which is to be purged with a gentle stream of gas. The lower electrode must be porous to gas to allow for gas exchange with the feed gas. The cell is typically used with gas diffusion electrodes (such as for Li-air) or with Li-ion battery electrodes with a meshed current collector. The unique design minimizes the back mixing of the gas from the flowfield back into the headspace. It is thus very suitable for time-resolved gas analysis with a mass spectrometer, for example.

All PAT-Cell-Gas variants can be operated directly with the PAT-Tester-x potentiostat. If used with a 3rd party potentiostat, the PAT-Press-Box is required for all variants equipped with a pressure sensor.

Working modes
There are two dedicated lower plunger available for the PAT-Cell-Gas for different testing purposes.
02-02-PAT-Cell-Gas-01

Mode 1: Air mode
The lower plunger with perforated plate allows for electrochemical characterization of gas diffusion electrodes used for instance in Li-air batteries. The lower electrode is contacted by and “breathes” through the perforated stainless steel current collector supporting it. During operation, the pressure gradient building up between cell headroom and the gas volume below the perforated plate effectively prevents back-mixing. The relatively large volume below the perforated is at the expense of time resolution, but makes this solution robust against clogging of the gas path.

PAT-Core configuration example

02-02-PAT-Cell-Gas-02

Mode 2: OEMS mode
The PAT-Core setup using a lower plunger with a flow field provides almost perfect plug-flow of the purge gas, being essential for quantitative time-resolved analysis. Gases evolved or consumed at the working electrode may be analysed through the composition change of the gas stream that is to be passed along the spiral-type flow field below the working electrode. The composition of the outgoing gas can be analyzed by e.g. mass spectrometry. The pressure gradient between cell headroom and spiral-type flow field effectively prevents back mixing. This and the tiny gas volume of the flow field ensure the best possible time resolution.

PAT-Core configuration example

02-02-PAT-Cell-Gas-03

02-02-PAT-Cell-Gas-04

Dead volume (PAT-Cell-Gas with metal seal lid)

 

相關產品

PAT-Cell-Press

PAT-Cell-Press

Leakproof test cell for measuring gas evolution.

•PAT-Core design with or without reference electrode
•Laser welded pressure sensor, 0 to 3 bar abs.
•Electrode feedthroughs with glass-to-metal seals

ECC-DEMS

ECC-DEMS

The ECC-DEMS is dedicated to the in-situ gas analysis in aprotic Li-air and conventional Li-ion systems.

•Time-resolved gas analysis
•Reliable low leakage sealing with PE washer
•Electrodes are easily accessible for post-mortem analysis

ECC-Air

ECC-Air

Test cell for the electrochemical characterization of gas diffusion electrodes in aprotic electrolytes

•Fast assembly and dismantling and easy cleaning of cell components
•Small and defined electrolyte volume down to 0.05 cm3
•Electrodes are easily accessible for post-mortem analysis

ECC-Air-Ni

ECC-Air-Ni

Test cell for electrochemical characterization of gas diffusion electrodes in aqueous electrolytes

•Fast assembly and dismantling and easy cleaning of cell components
•Materials in media contact are nickel and PEEK
•Upper electrode is contacted by and breathes through a perforated plate (current collector) made of nickel

代理品牌

測試治具-氣體分析測試治具

測試治具-氣體分析測試治具

分析不同非質子性電解液中的氣體產生與擴散情形。

洽詢車

你的洽詢車總計 0 件產品

產品比較

你的比較總計 0 件產品

依據歐盟施行的個人資料保護法,我們致力於保護您的個人資料並提供您對個人資料的掌握。
按一下「全部接受」,代表您允許我們置放 Cookie 來提升您在本網站上的使用體驗、協助我們分析網站效能和使用狀況,以及讓我們投放相關聯的行銷內容。您可以在下方管理 Cookie 設定。 按一下「確認」即代表您同意採用目前的設定。
管理Cookies

隱私權偏好設定中心

依據歐盟施行的個人資料保護法,我們致力於保護您的個人資料並提供您對個人資料的掌握。
按一下「全部接受」,代表您允許我們置放 Cookie 來提升您在本網站上的使用體驗、協助我們分析網站效能和使用狀況,以及讓我們投放相關聯的行銷內容。您可以在下方管理 Cookie 設定。 按一下「確認」即代表您同意採用目前的設定。
查看隱私權政策

管理同意設定

必要的Cookie

一律啟用
網站運行離不開這些 Cookie 且您不能在系統中將其關閉。通常僅根據您所做出的操作(即服務請求)來設置這些 Cookie,如設置隱私偏好、登錄或填充表格。您可以將您的瀏覽器設置為阻止或向您提示這些 Cookie,但可能會導致某些網站功能無法工作。