Analysis of liquefied and compressed gases according to Standards ASTM D 2163 and D 2598
分享:

The MobilGC is a gas-phase chromatograph and easy to use. Measurement of gas composition according to ASTM standards D 2163 (LPG analysis) and D 2598 (evaluation method) is possible with combination of the Sampling Box.

The rugged case and the internal gas supply allow the LPG analysis on-site at the measurement points. The measurement sensitivity fulfills the requirements of the ASTM standards: 0.1 to 100 % of clean gas components.

For sample preparation the Sampling Box has to be connected with the gas bottle or sampling line of the liquefied gas and with a sampling bag. 5 ml liquefied gas is taken and transferred to the sampling bag for expansion. In this way you can also make gas mixtures by addition of further components, e. g. for calibration.

For analysis the sampling bag has to be connected with the MobilGC. A heated column separates the gas sample. With the comfortable software of MobilGC an easy chromatogram evaluation according to standards is possible. The integrated expert evaluation system shows the result as concentration and additionally as total MON number or as MON value separately for each component.

Applications

The analytical system is suitable for (depending on type of chromatography column)

  • Determination of LPG composition
  • Measurement of Motor octane number (MON)
  • Check purity of LPG (content of pentane)
  • Analysis of refrigerants
  • Production and measurement of calibration mixtures

Advantages

  • Simple sample preparation with Sampling Box
  • Sample loop with 5 ml volume (also other sizes applicable)
  • MobilGC with internal carrier gas supply for on-site analysis
  • With up to 80 operating hours
  • Easy refilling of gas supply
  • Measurement sensitivity 0.1 to 100 %
  • Result as concentration, as total MON number or as MON value for each component

MobilGC with thermal conductivity detector (TCD):

  • Robust device with simple handling
  • Only one gas type required
  • Helium as carrier gas (according to standard ASTM D 2163)
  • Simple sample handling
MobilGC  
Measurement range: 0.1 ... 100 %
Resolution: 0.01 %
Typical duration: 2 … 30 min (depending on sample)
Temperature of column oven: Max. 250 °C,
controllable with individual temperature program
Internal gas supply: Approx. 80 h operating period
Power supply: 230 V / 50 Hz
Power input: Up to 240 W
Dimensions: 56 x 46 x 32 cm  (W x H x D)
Weight: 23 kg
   
Sampling Box  
Sample volume: Sample loop with 5 ml volume
(also other sizes applicable)
Sample pressure: Max. 10 bar
Dimensions: 17 x 9 x 20 cm (W x H x D)
Weight: 1 kg

相關產品

MobilGC 2

MobilGC 2

Portable gas chromatograph in a robust case with internal gas supply for use on-site and in-lab

MobilGC for cooling gases

MobilGC for cooling gases

Portable and robust gas analyzer for mobile use in a harbour situation

GasExtractor for gas in oil analysis

GasExtractor for gas in oil analysis

Completely automated system that extracts gases from oils and other highly viscous liquids by vacuum

Fermentation test system GärOnA

Fermentation test system GärOnA

Automated lab fermentation system with online gas analysis

代理品牌

氣體分析

氣體分析

高效流程、精確結果、最大靈活性——這正是我們分析系統的核心價值。

無論是氣相層析、油品脫氣,還是沼氣發酵,我們的設備皆採用最先進的技術,自動化操作流程、減少錯誤,並提供最高等級的分析準確性。

洽詢車

你的洽詢車總計 0 件產品

產品比較

你的比較總計 0 件產品

依據歐盟施行的個人資料保護法,我們致力於保護您的個人資料並提供您對個人資料的掌握。
按一下「全部接受」,代表您允許我們置放 Cookie 來提升您在本網站上的使用體驗、協助我們分析網站效能和使用狀況,以及讓我們投放相關聯的行銷內容。您可以在下方管理 Cookie 設定。 按一下「確認」即代表您同意採用目前的設定。
管理Cookies

隱私權偏好設定中心

依據歐盟施行的個人資料保護法,我們致力於保護您的個人資料並提供您對個人資料的掌握。
按一下「全部接受」,代表您允許我們置放 Cookie 來提升您在本網站上的使用體驗、協助我們分析網站效能和使用狀況,以及讓我們投放相關聯的行銷內容。您可以在下方管理 Cookie 設定。 按一下「確認」即代表您同意採用目前的設定。
查看隱私權政策

管理同意設定

必要的Cookie

一律啟用
網站運行離不開這些 Cookie 且您不能在系統中將其關閉。通常僅根據您所做出的操作(即服務請求)來設置這些 Cookie,如設置隱私偏好、登錄或填充表格。您可以將您的瀏覽器設置為阻止或向您提示這些 Cookie,但可能會導致某些網站功能無法工作。